Tissue impedance
Place a piece of liver between silver electrodes, switch on the generator and measure |Z| and φ while changing the frequency from 100 Hz to 3 MHz.
The “Oscilloscope” view shows the U and I traces and |Z|(f) curves; the “Circuit” view shows the equivalent circuit, the Cole arc and the K values.
In this lab
- |Z| = √(R² + X²)
- X_C = 1/(2πfC)
- tan φ = X/R
- K = |Z(10 kHz)| / |Z(1 MHz)|
What you learn
We measure tissue impedance at different frequencies, observe the dispersion and judge viability with the polarisation coefficient.
Laws and formulas
|Z| = √(R² + X²) — Total impedance.
X_C = 1/(2πfC) — Capacitive reactance.
tg φ = X/R — Phase shift.
K = Z(10 kHz)/Z(1 MHz) — Tarusov’s coefficient.
Equipment
- Measuring cell — a piece of liver between silver plate electrodes.
- Generator and oscilloscope — 100 Hz to 3 MHz, U = 1 V; the U and I traces.
Common mistakes
- Measuring with DC polarises the electrodes.
- Overheating the sample damages the tissue.
In real life
- Bioimpedance scales estimate body fat and water.
- Rheography gauges organ blood filling from impedance changes.