X-rays
Switch on the X-ray tube, choose the voltage, current and aluminium filter, and place a hand phantom or a stepped Al wedge on the detector.
The “Spectrum” view shows the spectrum against λ with λ_min, the Kα and Kβ lines and a cursor; the “Image” view shows the radiograph, detector signal and contrast.
In this lab
- λ_min = hc/(eU), hc = 1240 pm·kV
- I = I₀·e^(−μx)
- d½ = ln2/μ
- W: Kα 59 keV, Kβ 67 keV
What you learn
We study the X-ray tube spectrum: find Planck’s constant from the Duane–Hunt law, see the characteristic lines, and examine attenuation and image contrast.
Laws and formulas
λ_min = hc/(eU) — The Duane–Hunt law.
hc = 1240 pm·kV — A handy form.
I = I₀·e^(−μx) — Attenuation.
d½ = ln2/μ — The half-value layer.
Equipment
- X-ray tube — a cathode and rotating tungsten anode, 40–120 kV.
- Collimator and filter — limits the beam; Al 0–10 mm.
- Detector — measures the transmitted beam and forms the image.
Common mistakes
- Losing contrast by raising the voltage too far.
- Working without a filter gives the skin an extra dose.
In real life
- CT rebuilds a slice from hundreds of X-ray projections.
- Mammography uses low voltage (25–30 kV) for soft-tissue contrast.