Red cell size
Switch the laser on, choose a blood smear and the screen distance; fit the cursor to the first dark ring and find the red cell diameter.
The “Screen” view shows the diffraction pattern and intensity profile; “Microscope” shows the cells and their size distribution.
In this lab
- sin θ₁ = 1.22·λ/d
- tan θ₁ = R/L
- normal: d ≈ 7.5 µm
What you learn
From the diffraction rings of a laser beam passing through a blood smear we find the mean red cell diameter and spot micro- and macrocytosis in patients’ blood.
Laws and formulas
sin θ₁ = 1.22·λ/d — The first dark ring (Airy).
tg θ₁ = R/L — The ring radius on the screen.
Equipment
- Laser — red (650 nm) and green (532 nm).
- Blood smear — a thin film of blood on a glass slide.
- Screen — with a millimetre grid, sliding along the optical bench.
Common mistakes
- Measuring the first bright ring gives too small a d.
- Using the ring diameter instead of the radius halves d.
In real life
- Haematology analysers size cells from light scattering.
- MCV (mean cell volume) is the key index for classifying anaemia.