Dosimetry
Open the ¹³⁷Cs or ⁶⁰Co source in its lead container, slide the Geiger dosimeter along the rule, add shield plates and count the pulses.
The “Graphs” view shows dose rate against distance and shield thickness; the “Safety” view shows radiation types, dose units and typical doses.
In this lab
- Ḣ = Γ·A / r²
- Ḣ = Ḣ₀·e^(−μx), d½ = ln2/μ
- δN = √N
- background ≈ 0.12 µSv/h
What you learn
With a Geiger dosimeter we measure the gamma dose rate and test the inverse-square law and shielding with different materials.
Laws and formulas
Ḣ = Γ·A / r² — A point source.
Ḣ = Ḣ₀·e^(−μx) — Shielding.
d½ = ln2/μ — The half-value layer.
δN = √N — Counting error.
Equipment
- Gamma source — ¹³⁷Cs (740 kBq, 662 keV) or ⁶⁰Co (148 kBq, 1.17 and 1.33 MeV) in a lead pot.
- Geiger dosimeter — counts pulses and shows the dose rate.
- Shield plates — Pb 3 mm, Fe 10 mm, concrete 25 mm.
Common mistakes
- Not subtracting background: large errors at long range.
- Counting too briefly: few counts, big error.
In real life
- Radiologists wear personal dosimeter badges.
- X-ray room walls are lined with lead or barite concrete.