Quantum interference

A vacuum tube holds a particle source, a double-slit barrier and a movable detector screen. With a strong beam the screen shows bright and dark bands spaced Δy = λL/d.

Send particles one at a time: each lands at a random point, yet after thousands the same bands appear. Put a detector at the slits and the interference vanishes.

In this lab

  • Δy = λL/d: band spacing
  • λ = h/(m·v): the de Broglie wavelength
  • P(y) ∝ |ψ|²: probability
  • measuring Planck's constant

What you learn

In the double-slit experiment we see the wave nature of light and of matter (electrons, neutrons, atoms), watch interference build up from single particles, and measure a laser's wavelength and Planck's constant.

Laws and formulas

Δy = λL / d — The distance between neighbouring bright bands.

  • λ — wavelength
  • L — distance to the screen
  • d — slit separation

λ = h / (m·v) — The de Broglie wavelength of any moving particle.

P(y) ∝ |ψ(y)|² — The chance of a particle landing at a point is proportional to the wave function squared.

Equipment

  • Particle source — a laser (photons), an electron gun, or a neutron or helium-atom beam.
  • Double-slit barrier — choose the separation d; one slit can be covered or a detector added.
  • Detector screen — records where each particle lands; the distance L can change.
  • Vacuum tube — so air molecules do not scatter the particles.

Common mistakes

  • Measuring between neighbouring bands gives a big error; measure between the ±n-th bands and divide by 2n.
  • A single particle interferes too: the bands do not come from particles colliding.

In real life

  • Electron microscopes use the very short wavelength of electrons.
  • Neutron diffraction reveals the structure of materials.
  • Quantum computers and quantum cryptography rely on superposition and the effect of measurement.