Calorimeter

A cut-away calorimeter: an aluminium cup, insulation, a stirrer and a heater coil. Beside it stand a boiler, a balance, a digital thermometer and a power supply.

A metal heated to 100 °C in boiling water goes into cold water and the temperatures even out. “Graph” shows the heat balance, “Molecules” shows particle motion.

In this lab

  • Q = c·m·ΔT: quantity of heat
  • Q₁ = Q₂: heat balance
  • Q = U·I·t: electric heating
  • the specific heat of a metal and of water

What you learn

We watch heat exchange between hot and cold bodies, check the heat-balance equation and measure the specific heat capacity of a metal and of a liquid.

Laws and formulas

Q = c·m·ΔT — The heat needed to warm a body.

  • c — specific heat capacity, J/(kg·K)
  • ΔT — temperature change

Q₁ = Q₂ — Heat balance: the heat given by the hot body equals the heat taken by the cold one.

Q = U·I·t — The heat released by an electric heater (Joule’s law).

Equipment

  • Calorimeter — an inner aluminium cup, insulation and an outer shell; C = 50 J/K.
  • Stirrer — evens out the liquid temperature and speeds up the exchange.
  • Boiler — heats the sample to 100 °C.
  • Heater and power supply — a 4 Ω coil; U = 6, 9, 12 V.
  • Digital thermometer and balance — measure temperature to 0.1 °C and mass to 1 g.

Common mistakes

  • Recording θ before equilibrium gives a wrong c.
  • Ignoring the heat capacity C of the calorimeter itself.
  • The sample cools a little in air while being moved.

In real life

  • Water’s c is large: the climate by the sea is milder, and water cools engines well.
  • Food calories are measured by burning it in a calorimeter.
  • Water heating systems in homes and greenhouses.